The recoil will not pull or is difficult to pull

Alicia

Last Update 3 tahun yang lalu

Possible Cause

  1. Blower housing is clogged with debris.
  2. Oil level is low.
  3. The recoil is tangled up on itself.
  4. There is debris in the recoil.

Correction

  1. Make sure the engine has had time to cool. Remove the spark plug wire. Disconnect any hoses attached to the housing, remove the exit chute and check for any debris inside the blower housing. Remove any debris, re-attach items and try re-starting the engine.
  2. Check the engine oil level, the engine may be seized. Fill oil if necessary.
  3. Disconnect the spark plug wire, reach into the blower housing. Slowly turn the impeller by hand counter-clockwise, at the same time pull the starter cord. The rope should pull out. Reconnect the spark plug and try re-starting the engine.
  4. Locate and remove the 4 bolts that secure the recoil housing to the engine. Remove housing check for debris and clean if necessary. Re-install the housing and try re-starting the engine.